Addressing a Condensation Issue in Keith
We were approached by a local contractor to help with the issue of condensation in this distillery pump house. Discharge of hot water was causing condensation to form on the steel roof and beams, dripping onto live switchgear…the answer was to spray 100mm of Icynene Spray Foam to the roof and purlins. LDC-70 was used in this application as it gives a marginally better u-Value overall, and it is certified for use with DC315 fireproof coating. The foam was sprayed to the required depth with our Graco E30i dual-proportioner reactor, then the fireproof coating was applied with an airless sprayer.
![IMG 9096 Case Studies IMG_9096](https://www.jhjgroup.co.uk/wp-content/uploads/2020/07/IMG_9096-300x225.jpg)
![IMG 9098 Case Studies IMG_9098](https://www.jhjgroup.co.uk/wp-content/uploads/2020/07/IMG_9098-300x225.jpg)
![3f958474 34a9 44d9 a093 77bfbc157b69 Case Studies 3f958474-34a9-44d9-a093-77bfbc157b69](https://www.jhjgroup.co.uk/wp-content/uploads/2020/07/3f958474-34a9-44d9-a093-77bfbc157b69-225x300.jpg)
![2839dfc6 43d6 4c9f 983b 78a65248f628 Case Studies 2839dfc6-43d6-4c9f-983b-78a65248f628](https://www.jhjgroup.co.uk/wp-content/uploads/2020/07/2839dfc6-43d6-4c9f-983b-78a65248f628-225x300.jpg)
![a564f6ce 3bef 4b13 84f8 c241128f33ff Case Studies a564f6ce-3bef-4b13-84f8-c241128f33ff](https://www.jhjgroup.co.uk/wp-content/uploads/2020/07/a564f6ce-3bef-4b13-84f8-c241128f33ff-225x300.jpg)
![ad81f393 007a 4277 8742 497b6b0a15ea 1 Case Studies Icynene Project property photo](https://www.jhjgroup.co.uk/wp-content/uploads/2020/04/ad81f393-007a-4277-8742-497b6b0a15ea-1-300x225.jpg)
![11b6a3f8 d918 4af0 968a e8ff2460627e Case Studies Icynene Project AND JHJ](https://www.jhjgroup.co.uk/wp-content/uploads/2020/04/11b6a3f8-d918-4af0-968a-e8ff2460627e-300x225.jpg)
![IMG 6971 Case Studies Icynene Case Study Curved Roof](https://www.jhjgroup.co.uk/wp-content/uploads/2020/04/IMG_6971-300x225.jpg)
![IMG 7002 Case Studies Icynene Project Curved Roof](https://www.jhjgroup.co.uk/wp-content/uploads/2020/04/IMG_7002-300x225.jpg)
![IMG 7005 Case Studies Icynene Project Property](https://www.jhjgroup.co.uk/wp-content/uploads/2020/04/IMG_7005-300x225.jpg)
![IMG 7007 Case Studies Icynen Insulation completed new build in Aberdeenshire](https://www.jhjgroup.co.uk/wp-content/uploads/2020/04/IMG_7007-300x225.jpg)
![a9a51d7b b193 48db a4c2 d0c68ce9ca0c Case Studies Timber Curved Roof Prep](https://www.jhjgroup.co.uk/wp-content/uploads/2020/04/a9a51d7b-b193-48db-a4c2-d0c68ce9ca0c-225x300.jpg)
![IMG 7091 1 Case Studies Icynene Spray Foam Curved Roof](https://www.jhjgroup.co.uk/wp-content/uploads/2020/04/IMG_7091-1-300x225.jpg)
An original New Build in Fetterangus, Aberdeenshire
Icynene Insulation was sprayed to the curved roof components between the rafters with a flash covering over the faces to reduce cold-bridging, and trimmed to a brander to allow for fixing of plasterboard.
Insulation was sprayed to any exposed steelwork and steel beams and box sections were injected.
The roof resembles the upturned hull of a boat…a striking design feature that would have been a challenge to insulate and make airtight using traditional forms of insulation alone.
A High Performance New Build in Inverness
This new build in Inverness was insulated with 200mm Spray Foam Insulation to the walls and 250mm to the roof; the final airtest result was 1.1 ACH (Air Changes per Hour) which surpassed requirements ensuring that the MVHR system worked at its optimum efficiency. For reference, the building control requirement is 5 ACH, and Passive House Standard is 0.6 ACH. When forming a thermal envelope with Spray Foam, these high levels of airtightness are easily achieved and consideration must be given to ventilation requirements. We consulted with MVHR specialists Airtightbuild.com to ensure the design worked and the building performs at its best.
![Retrofit Case Studies New build insulation in Inverness](https://www.jhjgroup.co.uk/wp-content/uploads/2020/03/Retrofit.jpg)
![Retrofit1 Case Studies Icynene LDC-50 Spray Foam](https://www.jhjgroup.co.uk/wp-content/uploads/2020/03/Retrofit1.jpg)
![Retrofit2 Case Studies Airtightness Testing ot 0.1](https://www.jhjgroup.co.uk/wp-content/uploads/2020/03/Retrofit2.jpg)
![IMG 07681 Case Studies Masking and protection to timber](https://www.jhjgroup.co.uk/wp-content/uploads/2020/05/IMG_07681-1024x768.jpg)
![IMG 3758 Case Studies Joinery Machinery Pallets Photo](https://www.jhjgroup.co.uk/wp-content/uploads/2020/05/IMG_3758-300x225.jpeg)
![Copy IMG 3543 Case Studies Copy IMG_3543](https://www.jhjgroup.co.uk/wp-content/uploads/2023/03/Copy-IMG_3543-251x300.jpg)
An industrial application in Aberdeenshire
The main issue was condensation forming and dripping from the purlins…Closed-cell Insulation was sprayed to the fibre sheet roof components and a cross both faces of the steel purlins to reduce cold-bridging and eliminate the condensation…also helping to reduce heat loss in the large, multi-functional space.
A commercial Warehouse in Banff
This steel framed and profile clad warehouse was insulated with LDC-70 Icynene Spray Foam Insulation to increase thermal performance and eliminate condensation. As is often the case with this type of construction, there was a problem with condensation forming and dripping off the purlins causing damage to stored items and equipment. The rooflights were framed out and retained to allow for natural light. The application was subsequently treated with DC315 fireproof coating to achieve a Fire Rating of 0.
![Case Study3 Case Studies Banff Warehouse Icynene Project](https://www.jhjgroup.co.uk/wp-content/uploads/2020/03/Case-Study3.jpg)
![Case Study4 Case Studies Warehouse Icynene Project Installation](https://www.jhjgroup.co.uk/wp-content/uploads/2020/03/Case-Study4.jpg)
![Case Study5 Case Studies Warehouse Icynene Project Exterior](https://www.jhjgroup.co.uk/wp-content/uploads/2020/03/Case-Study5.jpg)
Why Choose Spray Foam?
Spray Foam Insulation is a system that delivers up to 50% greater energy savings when compared to other home insulation products. Our choice of open-cell foam has achieved BBA and KIWA certification, and our closed-cell product provides a Class 1 Fire Rating. It’s an investment that you will rarely see but you will feel the benefits daily. Why not choose the peace of mind that comes with a healthier, quieter, more energy efficient indoor environment?
Did you know that up to 40% of your home’s air, whether heated or cooled, can be lost via air leakage? Your heating system or air conditioner can end up working harder to make up for the air that is escaping your home, which can drive up your monthly heating and cooling bills. Icynene spray foam insulation can help by eliminating air leakage as well as addressing conductive heat loss.
Reduce noise – Icynene open-cell spray foam can help reduce sound from noisy indoor rooms such as media rooms and laundry rooms, outdoor noises such as traffic and playgrounds, and transferred noise such as flushing toilets.
Buildings insulated with Icynene can achieve extremely high levels of airtightness without the need for air barriers, tapes or sealants – saving time and money. Spray foam helps achieve building compliance assuring clients and contractors peace of mind, and a lifetime of high performance.
Application of closed-cell foam to steel and fibre roofs can help save energy and prevents condensation problems which can be damaging and costly for your business…
Minimising the flow of random airborne moisture entering your home helps protect against mould growth that can lead to conditions such as asthma and allergies which can cause symptoms such as itchy eyes, sneezing, and coughing. Most of the moisture that enters the walls of your home is carried in the air.
Architects have to be aware of the limits housing materials impose; laying sheets of fiberglass and rolls of foil or rigid board insulation can determine the shapes and angles a floor plan can use. Icynene spray foam, on the other hand, moulds itself to all kinds of shapes allowing for alternative and unique design layouts.
Buildings insulated with Icynene can achieve extremely high levels of airtightness without the need for air barriers, tapes or sealants – saving time and money. Spray foam helps achieve building compliance assuring clients and contractors peace of mind, and a lifetime of high performance.
Makes your working-from-home space warmer and more comfortable!